{"product_id":"riken-keiki-gx-3r-pro-5-gas-detector-with-co-marine-confined-space-gas-monitor-cpd-w6x1hmb1-y-00","title":"Riken Keiki GX-3R Pro 5 Gas Detector with CO₂ – Marine Confined Space Gas Monitor (CPD-W6X1HMB1-Y-00)","description":"\u003cp data-start=\"424\" data-end=\"593\"\u003e\u003cstrong\u003ePLEASE NOTE THAT AVAILABILITY ON THIS UNIT IS CURRENTLY UP TO 5 MONTHS DUE TO HIGH DEMAND\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"424\" data-end=\"593\"\u003eThe \u003cstrong data-start=\"428\" data-end=\"453\"\u003eRiken Keiki GX-3R Pro\u003c\/strong\u003e is an advanced, ultra-compact \u003cstrong data-start=\"484\" data-end=\"510\"\u003e5 gas personal monitor\u003c\/strong\u003e designed for use in confined spaces, offshore environments, and marine operations.\u003c\/p\u003e\n\u003cp data-start=\"595\" data-end=\"998\"\u003eAs enclosed space safety guidance continues to evolve under the \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eInternational Maritime Organization\u003c\/span\u003e\u003c\/span\u003e, there is increasing emphasis on \u003cstrong data-start=\"730\" data-end=\"775\"\u003eaccurate carbon dioxide (CO₂) measurement\u003c\/strong\u003e during pre-entry atmospheric testing. This compact, intrinsically safe gas detector provides reliable CO₂ monitoring alongside other critical gases, making it a future-ready solution for vessels and offshore installations.\u003c\/p\u003e\n\u003ch2 data-section-id=\"amjeev\" data-start=\"1005\" data-end=\"1060\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1008\" data-end=\"1060\"\u003eWhy CO₂ Detection Matters in Marine Environments\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1062\" data-end=\"1229\"\u003eNew and emerging guidance for enclosed space entry highlights the importance of monitoring carbon dioxide levels, particularly in oxygen-depleted or inert atmospheres.\u003c\/p\u003e\n\u003cp data-start=\"1231\" data-end=\"1348\"\u003eMany traditional \u003cstrong data-start=\"1248\" data-end=\"1267\"\u003e4 gas detectors\u003c\/strong\u003e used on ships do not measure CO₂, creating a potential gap in safety procedures.\u003c\/p\u003e\n\u003cp data-start=\"1350\" data-end=\"1395\"\u003eThe GX-3R Pro helps address this by enabling:\u003c\/p\u003e\n\u003cul data-start=\"1397\" data-end=\"1638\"\u003e\n\u003cli data-section-id=\"1dkkba4\" data-start=\"1397\" data-end=\"1457\"\u003eAccurate \u003cstrong data-start=\"1408\" data-end=\"1455\"\u003eCO₂ gas detection (0–5% \/ 50,000 ppm range)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"8ub4qw\" data-start=\"1458\" data-end=\"1514\"\u003eImproved risk assessment before confined space entry\u003c\/li\u003e\n\u003cli data-section-id=\"1z8h9s\" data-start=\"1515\" data-end=\"1581\"\u003eEnhanced compliance with evolving maritime safety expectations\u003c\/li\u003e\n\u003cli data-section-id=\"her6cb\" data-start=\"1582\" data-end=\"1638\"\u003eSafer working conditions for crew in enclosed spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"vva24c\" data-start=\"1645\" data-end=\"1687\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1648\" data-end=\"1687\"\u003eMarine-Ready Gas Detection Solution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1689\" data-end=\"1812\"\u003eThis model is available with \u003cstrong data-start=\"1718\" data-end=\"1753\"\u003eMED (Wheelmark) marine approval\u003c\/strong\u003e, making it suitable for use on vessels operating globally.\u003c\/p\u003e\n\u003cp data-start=\"1814\" data-end=\"1872\"\u003eIt is certified to key hazardous area standards including:\u003c\/p\u003e\n\u003cul data-start=\"1874\" data-end=\"1957\"\u003e\n\u003cli data-section-id=\"17wgcs5\" data-start=\"1874\" data-end=\"1915\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eATEX Directive\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1gcjogl\" data-start=\"1916\" data-end=\"1957\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eIECEx\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1959\" data-end=\"2059\"\u003eThis ensures suitability for offshore, marine, and industrial applications where safety is critical.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1pi78xj\" data-start=\"2066\" data-end=\"2096\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2069\" data-end=\"2096\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-section-id=\"gqzj08\" data-start=\"2098\" data-end=\"2134\"\u003e⚓ Compact \u0026amp; Lightweight Design\u003c\/h3\u003e\n\u003cul data-start=\"2135\" data-end=\"2316\"\u003e\n\u003cli data-section-id=\"w7nx80\" data-start=\"2135\" data-end=\"2200\"\u003eOne of the \u003cstrong data-start=\"2148\" data-end=\"2198\"\u003esmallest and lightest 5 gas monitors available\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l8c0lf\" data-start=\"2201\" data-end=\"2248\"\u003eApprox. \u003cstrong data-start=\"2211\" data-end=\"2219\"\u003e120g\u003c\/strong\u003e, designed for all-day wear\u003c\/li\u003e\n\u003cli data-section-id=\"14au1jt\" data-start=\"2249\" data-end=\"2316\"\u003eFits easily in the breathing zone without interfering with work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"zkw409\" data-start=\"2318\" data-end=\"2349\"\u003e📡 Bluetooth Connectivity\u003c\/h3\u003e\n\u003cul data-start=\"2350\" data-end=\"2497\"\u003e\n\u003cli data-section-id=\"1akb0gq\" data-start=\"2350\" data-end=\"2396\"\u003eWireless connection via iOS \u0026amp; Android apps\u003c\/li\u003e\n\u003cli data-section-id=\"4kuhor\" data-start=\"2397\" data-end=\"2445\"\u003eEnables real-time data access and monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1xtqm81\" data-start=\"2446\" data-end=\"2497\"\u003eSupports improved safety reporting and analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1c3i78t\" data-start=\"2499\" data-end=\"2534\"\u003e👤 Worker Protection Features\u003c\/h3\u003e\n\u003cul data-start=\"2535\" data-end=\"2667\"\u003e\n\u003cli data-section-id=\"12jo3tr\" data-start=\"2535\" data-end=\"2580\"\u003e\n\u003cstrong data-start=\"2537\" data-end=\"2555\"\u003eMan-down alarm\u003c\/strong\u003e for lone worker safety\u003c\/li\u003e\n\u003cli data-section-id=\"mk9ngl\" data-start=\"2581\" data-end=\"2610\"\u003ePanic alarm functionality\u003c\/li\u003e\n\u003cli data-section-id=\"1ex5hz5\" data-start=\"2611\" data-end=\"2667\"\u003eAudible, visual, and vibration alerts (95 dB buzzer)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"bzrrti\" data-start=\"2669\" data-end=\"2704\"\u003e🧠 Advanced Sensor Technology\u003c\/h3\u003e\n\u003cul data-start=\"2705\" data-end=\"2874\"\u003e\n\u003cli data-section-id=\"16xl431\" data-start=\"2705\" data-end=\"2758\"\u003e4-sensor platform delivering \u003cstrong data-start=\"2736\" data-end=\"2756\"\u003e5 gas capability\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fijmif\" data-start=\"2759\" data-end=\"2820\"\u003eIncludes \u003cstrong data-start=\"2770\" data-end=\"2793\"\u003einfrared CO₂ sensor\u003c\/strong\u003e for reliable measurement\u003c\/li\u003e\n\u003cli data-section-id=\"6mx6h\" data-start=\"2821\" data-end=\"2874\"\u003eLong-life sensors backed by a \u003cstrong data-start=\"2853\" data-end=\"2872\"\u003e3-year warranty\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"e9wzzl\" data-start=\"2876\" data-end=\"2902\"\u003e🔋 Long Battery Life\u003c\/h3\u003e\n\u003cul data-start=\"2903\" data-end=\"3037\"\u003e\n\u003cli data-section-id=\"1f07lg9\" data-start=\"2903\" data-end=\"2946\"\u003eUp to \u003cstrong data-start=\"2911\" data-end=\"2944\"\u003e40 hours continuous operation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vzjug8\" data-start=\"2947\" data-end=\"2997\"\u003eFast charging capability (approx. 180 minutes)\u003c\/li\u003e\n\u003cli data-section-id=\"1279251\" data-start=\"2998\" data-end=\"3037\"\u003eIdeal for offshore and extended use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"123i2ay\" data-start=\"3039\" data-end=\"3076\"\u003e💪 Built for Harsh Environments\u003c\/h3\u003e\n\u003cul data-start=\"3077\" data-end=\"3201\"\u003e\n\u003cli data-section-id=\"l2n4jj\" data-start=\"3077\" data-end=\"3130\"\u003e\n\u003cstrong data-start=\"3079\" data-end=\"3098\"\u003eIP66\/IP68 rated\u003c\/strong\u003e for water and dust resistance\u003c\/li\u003e\n\u003cli data-section-id=\"19ehvuy\" data-start=\"3131\" data-end=\"3161\"\u003eDrop-tested up to 7 metres\u003c\/li\u003e\n\u003cli data-section-id=\"4q7167\" data-start=\"3162\" data-end=\"3201\"\u003eOperating range: \u003cstrong data-start=\"3181\" data-end=\"3199\"\u003e-40°C to +60°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1ougavd\" data-start=\"3208\" data-end=\"3241\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3211\" data-end=\"3241\"\u003eGas Detection Capabilities\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3243\" data-end=\"3268\"\u003eThe GX-3R Pro can detect:\u003c\/p\u003e\n\u003cul data-start=\"3270\" data-end=\"3564\"\u003e\n\u003cli data-section-id=\"ue6t3a\" data-start=\"3270\" data-end=\"3285\"\u003eOxygen (O₂)\u003c\/li\u003e\n\u003cli data-section-id=\"1ynrlrw\" data-start=\"3286\" data-end=\"3313\"\u003eCombustible gases (LEL)\u003c\/li\u003e\n\u003cli data-section-id=\"125qoqt\" data-start=\"3314\" data-end=\"3338\"\u003eCarbon Monoxide (CO)\u003c\/li\u003e\n\u003cli data-section-id=\"1hturhq\" data-start=\"3339\" data-end=\"3366\"\u003eHydrogen Sulphide (H₂S)\u003c\/li\u003e\n\u003cli data-section-id=\"zs8rly\" data-start=\"3367\" data-end=\"3391\"\u003eCarbon Dioxide (CO₂)\u003c\/li\u003e\n\u003cli data-section-id=\"1hwb999\" data-start=\"3392\" data-end=\"3564\"\u003eOptional toxic gases:\n\u003cul data-start=\"3418\" data-end=\"3564\"\u003e\n\u003cli data-section-id=\"q5rdfo\" data-start=\"3418\" data-end=\"3435\"\u003eAmmonia (NH₃)\u003c\/li\u003e\n\u003cli data-section-id=\"txw4xm\" data-start=\"3438\" data-end=\"3464\"\u003eNitrogen Dioxide (NO₂)\u003c\/li\u003e\n\u003cli data-section-id=\"1nz7upc\" data-start=\"3467\" data-end=\"3492\"\u003eSulphur Dioxide (SO₂)\u003c\/li\u003e\n\u003cli data-section-id=\"1iq0b3p\" data-start=\"3495\" data-end=\"3521\"\u003eHydrogen Cyanide (HCN)\u003c\/li\u003e\n\u003cli data-section-id=\"1vkyggc\" data-start=\"3524\" data-end=\"3543\"\u003ePhosphine (PH₃)\u003c\/li\u003e\n\u003cli data-section-id=\"1enlsik\" data-start=\"3546\" data-end=\"3564\"\u003eChlorine (Cl₂)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"9pug5g\" data-start=\"3571\" data-end=\"3607\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3574\" data-end=\"3607\"\u003eData Logging \u0026amp; Alarm Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"3609\" data-end=\"3826\"\u003e\n\u003cli data-section-id=\"1io002g\" data-start=\"3609\" data-end=\"3651\"\u003eConfigurable alarm levels for each gas\u003c\/li\u003e\n\u003cli data-section-id=\"lnmfg5\" data-start=\"3652\" data-end=\"3683\"\u003eOver-range and fault alarms\u003c\/li\u003e\n\u003cli data-section-id=\"vzq19w\" data-start=\"3684\" data-end=\"3768\"\u003eInternal data logging:\n\u003cul data-start=\"3711\" data-end=\"3768\"\u003e\n\u003cli data-section-id=\"rqf50g\" data-start=\"3711\" data-end=\"3733\"\u003eUp to 3,600 events\u003c\/li\u003e\n\u003cli data-section-id=\"5slp8y\" data-start=\"3736\" data-end=\"3768\"\u003eUp to 300 hours of recording\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ln8peh\" data-start=\"3769\" data-end=\"3826\"\u003eAlarm types:\n\u003cul data-start=\"3786\" data-end=\"3826\"\u003e\n\u003cli data-section-id=\"m24zfg\" data-start=\"3786\" data-end=\"3796\"\u003eVisual\u003c\/li\u003e\n\u003cli data-section-id=\"1kd6yyi\" data-start=\"3799\" data-end=\"3810\"\u003eAudible\u003c\/li\u003e\n\u003cli data-section-id=\"105a5q2\" data-start=\"3813\" data-end=\"3826\"\u003eVibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"k0zlak\" data-start=\"3833\" data-end=\"3852\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3836\" data-end=\"3852\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"3854\" data-end=\"4077\"\u003e\n\u003cli data-section-id=\"hz411i\" data-start=\"3854\" data-end=\"3885\"\u003eMarine confined space entry\u003c\/li\u003e\n\u003cli data-section-id=\"1myqcfc\" data-start=\"3886\" data-end=\"3907\"\u003eShip engine rooms\u003c\/li\u003e\n\u003cli data-section-id=\"1pz5wvc\" data-start=\"3908\" data-end=\"3930\"\u003eOffshore platforms\u003c\/li\u003e\n\u003cli data-section-id=\"o8yjig\" data-start=\"3931\" data-end=\"3963\"\u003eTank cleaning and inspection\u003c\/li\u003e\n\u003cli data-section-id=\"crkha5\" data-start=\"3964\" data-end=\"3992\"\u003eGas detection programmes\u003c\/li\u003e\n\u003cli data-section-id=\"1mbw5q7\" data-start=\"3993\" data-end=\"4025\"\u003eIndustrial safety monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"qfzkyx\" data-start=\"4026\" data-end=\"4077\"\u003eHazardous environments requiring CO₂ monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"16hhj3p\" data-start=\"4084\" data-end=\"4120\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4087\" data-end=\"4120\"\u003eDesigned for Fleet Operations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4122\" data-end=\"4262\"\u003eThe GX-3R Pro is ideal for integration into \u003cstrong data-start=\"4166\" data-end=\"4205\"\u003efleet-wide gas detection programmes\u003c\/strong\u003e, helping operators standardise equipment across vessels.\u003c\/p\u003e\n\u003cp data-start=\"4264\" data-end=\"4303\"\u003eAt IM-M, we support global fleets with:\u003c\/p\u003e\n\u003cul data-start=\"4304\" data-end=\"4435\"\u003e\n\u003cli data-section-id=\"9eortd\" data-start=\"4304\" data-end=\"4324\"\u003eEquipment supply\u003c\/li\u003e\n\u003cli data-section-id=\"1g8f2z5\" data-start=\"4325\" data-end=\"4354\"\u003eCalibration and servicing\u003c\/li\u003e\n\u003cli data-section-id=\"19gj5ra\" data-start=\"4355\" data-end=\"4389\"\u003eInstrument rotation programmes\u003c\/li\u003e\n\u003cli data-section-id=\"pkvz4k\" data-start=\"4390\" data-end=\"4435\"\u003eTechnical support and compliance guidance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"84doct\" data-start=\"4442\" data-end=\"4469\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4445\" data-end=\"4469\"\u003eOptional Accessories\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4471\" data-end=\"4572\"\u003e\n\u003cli data-section-id=\"x8vuf0\" data-start=\"4471\" data-end=\"4503\"\u003eMulti-unit charging stations\u003c\/li\u003e\n\u003cli data-section-id=\"cnitim\" data-start=\"4504\" data-end=\"4533\"\u003eCommunication accessories\u003c\/li\u003e\n\u003cli data-section-id=\"ldwggw\" data-start=\"4534\" data-end=\"4572\"\u003eData transfer and management tools\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"id1bjs\" data-start=\"4579\" data-end=\"4610\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4582\" data-end=\"4610\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4612\" data-end=\"4914\"\u003e\n\u003cli data-section-id=\"njm0kh\" data-start=\"4612\" data-end=\"4671\"\u003eDetection: LEL, O₂, CO, H₂S, CO₂ + optional toxic gases\u003c\/li\u003e\n\u003cli data-section-id=\"rdkfiq\" data-start=\"4672\" data-end=\"4695\"\u003eSampling: Diffusion\u003c\/li\u003e\n\u003cli data-section-id=\"1jcxll4\" data-start=\"4696\" data-end=\"4733\"\u003ePower: Rechargeable Ni-MH battery\u003c\/li\u003e\n\u003cli data-section-id=\"kpdjna\" data-start=\"4734\" data-end=\"4772\"\u003eCharging time: Approx. 180 minutes\u003c\/li\u003e\n\u003cli data-section-id=\"1jih2q8\" data-start=\"4773\" data-end=\"4805\"\u003eBattery life: Up to 40 hours\u003c\/li\u003e\n\u003cli data-section-id=\"1vqpo24\" data-start=\"4806\" data-end=\"4830\"\u003eWeight: Approx. 120g\u003c\/li\u003e\n\u003cli data-section-id=\"1tkr4qv\" data-start=\"4831\" data-end=\"4866\"\u003eIngress protection: IP66 \/ IP68\u003c\/li\u003e\n\u003cli data-section-id=\"1pr9k1s\" data-start=\"4867\" data-end=\"4914\"\u003eCertifications: ATEX, IECEx, MED (optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0589\/1411\/1599\/files\/DATASHEET_GX-3R-PRO_PC0E-1010_2.pdf?v=1774447622\" title=\"Riken Keiki GX-3R Pro Datasheet\"\u003eRiken Keiki GX-3R Pro Datasheet\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0589\/1411\/1599\/files\/MANUAL_GX-3R-PRO__PT0E-1775.pdf?v=1774447647\" title=\"Riken Keiki GX-3R Pro User Manual\"\u003eRiken Keiki GX-3R Pro User Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Riken Keiki","offers":[{"title":"Default Title","offer_id":52847935815791,"sku":null,"price":1178.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0589\/1411\/1599\/files\/GX-3RPro_Weatherall_JPG.jpg?v=1774451194","url":"https:\/\/www.im-m.co.uk\/products\/riken-keiki-gx-3r-pro-5-gas-detector-with-co-marine-confined-space-gas-monitor-cpd-w6x1hmb1-y-00","provider":"IMM-UK","version":"1.0","type":"link"}