{"product_id":"drager-pac®-8000-single-gas-detector","title":"Dräger Pac® 8000 Single Gas Detector","description":"\u003ch2 data-section-id=\"109v3u2\" data-start=\"571\" data-end=\"633\" class=\"PDq2pG_selectionAnchorContainer\"\u003eAdvanced Personal Gas Monitoring for Hazardous Environments\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"635\" data-end=\"812\"\u003eThe \u003cstrong data-start=\"639\" data-end=\"659\"\u003eDräger Pac® 8000\u003c\/strong\u003e is a robust, reusable single-gas detector designed to provide reliable personal protection against hazardous gases in demanding industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"814\" data-end=\"1340\"\u003eCompact, durable and easy to operate, the Pac 8000 continuously monitors the surrounding atmosphere and provides rapid warning when dangerous gas concentrations are detected. With a wide selection of sensor options available, the instrument can be configured to measure a variety of toxic and special gases including \u003cstrong data-start=\"1131\" data-end=\"1281\"\u003ecarbon dioxide (CO₂), chlorine (Cl₂), hydrogen cyanide (HCN), ammonia (NH₃), phosphine (PH₃), ozone (O₃), nitrogen dioxide (NO₂), phosgene (COCl₂)\u003c\/strong\u003e and organic vapours. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1342\" data-end=\"1575\"\u003eUnlike disposable gas monitors, the Dräger Pac 8000 is designed for long-term service with replaceable filters, sensors and batteries, making it a cost-effective solution for organisations requiring dependable personal gas detection.\u003c\/p\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"1582\" data-end=\"1596\"\u003eKey Features\u003c\/h1\u003e\n\u003cp data-start=\"1598\" data-end=\"1709\"\u003e✔ \u003cstrong data-start=\"1600\" data-end=\"1625\"\u003eSingle-gas monitoring\u003c\/strong\u003e – continuously measures one selected gas according to your application requirements\u003c\/p\u003e\n\u003cp data-start=\"1711\" data-end=\"1884\"\u003e✔ \u003cstrong data-start=\"1713\" data-end=\"1738\"\u003eWide sensor selection\u003c\/strong\u003e – available for 29 different gases, including specialist gases used in industrial and chemical applications \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1886\" data-end=\"2054\"\u003e✔ \u003cstrong data-start=\"1888\" data-end=\"1916\"\u003eRugged industrial design\u003c\/strong\u003e – suitable for harsh working environments with a shock-resistant housing and IP68 protection rating \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2056\" data-end=\"2220\"\u003e✔ \u003cstrong data-start=\"2058\" data-end=\"2079\"\u003eLong battery life\u003c\/strong\u003e – powered for up to two years under normal operating conditions (depending on usage and configuration) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2222\" data-end=\"2349\"\u003e✔ \u003cstrong data-start=\"2224\" data-end=\"2250\"\u003eClear alarm indication\u003c\/strong\u003e – visual, audible and vibration alarms provide immediate warning when exposure limits are exceeded\u003c\/p\u003e\n\u003cp data-start=\"2351\" data-end=\"2474\"\u003e✔ \u003cstrong data-start=\"2353\" data-end=\"2381\"\u003eD-Light status indicator\u003c\/strong\u003e – confirms instrument readiness and operational status \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2476\" data-end=\"2602\"\u003e✔ \u003cstrong data-start=\"2478\" data-end=\"2510\"\u003eTLV, TWA and STEL monitoring\u003c\/strong\u003e – supports workplace exposure monitoring requirements \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2604\" data-end=\"2800\"\u003e✔ \u003cstrong data-start=\"2606\" data-end=\"2642\"\u003eBluetooth connectivity available\u003c\/strong\u003e – compatible configurations can transmit measurement data to Dräger Gas Detection Connect for improved fleet management \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1 data-section-id=\"ljd0sv\" data-start=\"2807\" data-end=\"2830\"\u003eAvailable Gas Sensors\u003c\/h1\u003e\n\u003cp data-start=\"2832\" data-end=\"2883\"\u003eThe Dräger Pac 8000 can be supplied configured for:\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2885\" data-end=\"3591\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2885\" data-end=\"2907\"\u003e\n\u003ctr data-start=\"2885\" data-end=\"2907\"\u003e\n\u003cth data-start=\"2885\" data-end=\"2891\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eGas\u003c\/th\u003e\n\u003cth data-start=\"2891\" data-end=\"2907\" data-col-size=\"md\" class=\"last:pe-10\"\u003eApplications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2918\" data-end=\"3591\"\u003e\n\u003ctr data-start=\"2918\" data-end=\"2986\"\u003e\n\u003ctd data-start=\"2918\" data-end=\"2941\" data-col-size=\"sm\"\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003ctd data-start=\"2941\" data-end=\"2986\" data-col-size=\"md\"\u003eIndustrial environments, combustion areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2987\" data-end=\"3055\"\u003e\n\u003ctd data-start=\"2987\" data-end=\"3013\" data-col-size=\"sm\"\u003eHydrogen Sulphide (H₂S)\u003c\/td\u003e\n\u003ctd data-start=\"3013\" data-end=\"3055\" data-col-size=\"md\"\u003eOil \u0026amp; gas, wastewater, confined spaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3056\" data-end=\"3103\"\u003e\n\u003ctd data-start=\"3056\" data-end=\"3080\" data-col-size=\"sm\"\u003eSulphur Dioxide (SO₂)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3080\" data-end=\"3103\"\u003eChemical processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3104\" data-end=\"3158\"\u003e\n\u003ctd data-start=\"3104\" data-end=\"3120\" data-col-size=\"sm\"\u003eAmmonia (NH₃)\u003c\/td\u003e\n\u003ctd data-start=\"3120\" data-end=\"3158\" data-col-size=\"md\"\u003eRefrigeration, chemical industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3159\" data-end=\"3212\"\u003e\n\u003ctd data-start=\"3159\" data-end=\"3176\" data-col-size=\"sm\"\u003eChlorine (Cl₂)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3176\" data-end=\"3212\"\u003eWater treatment, chemical plants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3213\" data-end=\"3289\"\u003e\n\u003ctd data-start=\"3213\" data-end=\"3236\" data-col-size=\"sm\"\u003eCarbon Dioxide (CO₂)\u003c\/td\u003e\n\u003ctd data-start=\"3236\" data-end=\"3289\" data-col-size=\"md\"\u003eConfined spaces, fermentation, process industries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3290\" data-end=\"3348\"\u003e\n\u003ctd data-start=\"3290\" data-end=\"3315\" data-col-size=\"sm\"\u003eNitrogen Dioxide (NO₂)\u003c\/td\u003e\n\u003ctd data-start=\"3315\" data-end=\"3348\" data-col-size=\"md\"\u003eCombustion processes, engines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3349\" data-end=\"3400\"\u003e\n\u003ctd data-start=\"3349\" data-end=\"3374\" data-col-size=\"sm\"\u003eHydrogen Cyanide (HCN)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3374\" data-end=\"3400\"\u003eChemical manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3401\" data-end=\"3446\"\u003e\n\u003ctd data-start=\"3401\" data-end=\"3419\" data-col-size=\"sm\"\u003ePhosphine (PH₃)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3419\" data-end=\"3446\"\u003eFumigation applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3447\" data-end=\"3490\"\u003e\n\u003ctd data-start=\"3447\" data-end=\"3460\" data-col-size=\"sm\"\u003eOzone (O₃)\u003c\/td\u003e\n\u003ctd data-start=\"3460\" data-end=\"3490\" data-col-size=\"md\"\u003eIndustrial ozone processes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3491\" data-end=\"3531\"\u003e\n\u003ctd data-start=\"3491\" data-end=\"3510\" data-col-size=\"sm\"\u003ePhosgene (COCl₂)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3510\" data-end=\"3531\"\u003eChemical industry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3532\" data-end=\"3591\"\u003e\n\u003ctd data-start=\"3532\" data-end=\"3562\" data-col-size=\"sm\"\u003eOrganic Vapours (OV \/ OV-A)\u003c\/td\u003e\n\u003ctd data-start=\"3562\" data-end=\"3591\" data-col-size=\"md\"\u003eSolvents and hydrocarbons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"3593\" data-end=\"3630\"\u003e \u003c\/p\u003e\n\u003ch1 data-section-id=\"bazihh\" data-start=\"3637\" data-end=\"3659\"\u003eTypical Applications\u003c\/h1\u003e\n\u003cp data-start=\"3661\" data-end=\"3697\"\u003eThe Dräger Pac 8000 is suitable for:\u003c\/p\u003e\n\u003cul data-start=\"3699\" data-end=\"3965\"\u003e\n\u003cli data-section-id=\"16am1zq\" data-start=\"3699\" data-end=\"3732\"\u003eConfined space entry monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"9z5czr\" data-start=\"3733\" data-end=\"3754\"\u003eChemical processing\u003c\/li\u003e\n\u003cli data-section-id=\"u54n22\" data-start=\"3755\" data-end=\"3783\"\u003eWater treatment facilities\u003c\/li\u003e\n\u003cli data-section-id=\"1phrpfx\" data-start=\"3784\" data-end=\"3806\"\u003eOil \u0026amp; gas industries\u003c\/li\u003e\n\u003cli data-section-id=\"4mxa1h\" data-start=\"3807\" data-end=\"3841\"\u003eMarine and offshore environments\u003c\/li\u003e\n\u003cli data-section-id=\"pq5ogs\" data-start=\"3842\" data-end=\"3864\"\u003eManufacturing plants\u003c\/li\u003e\n\u003cli data-section-id=\"s81s6\" data-start=\"3865\" data-end=\"3893\"\u003eRefrigeration applications\u003c\/li\u003e\n\u003cli data-section-id=\"1n962ua\" data-start=\"3894\" data-end=\"3914\"\u003eEmergency response\u003c\/li\u003e\n\u003cli data-section-id=\"1vuc9te\" data-start=\"3915\" data-end=\"3939\"\u003eIndustrial maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"1uxaq6l\" data-start=\"3940\" data-end=\"3965\"\u003eLaboratory environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"3972\" data-end=\"3998\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4000\" data-end=\"4505\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4000\" data-end=\"4027\"\u003e\n\u003ctr data-start=\"4000\" data-end=\"4027\"\u003e\n\u003cth data-start=\"4000\" data-end=\"4016\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"4016\" data-end=\"4027\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4034\" data-end=\"4505\"\u003e\n\u003ctr data-start=\"4034\" data-end=\"4072\"\u003e\n\u003ctd data-start=\"4034\" data-end=\"4049\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4049\" data-end=\"4072\"\u003eSingle Gas Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4073\" data-end=\"4120\"\u003e\n\u003ctd data-start=\"4073\" data-end=\"4090\" data-col-size=\"sm\"\u003eMeasured Gases\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4090\" data-end=\"4120\"\u003eOne gas (sensor dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4121\" data-end=\"4147\"\u003e\n\u003ctd data-start=\"4121\" data-end=\"4130\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4130\" data-end=\"4147\"\u003eApprox. 106 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4148\" data-end=\"4176\"\u003e\n\u003ctd data-start=\"4148\" data-end=\"4168\" data-col-size=\"sm\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4168\" data-end=\"4176\"\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4177\" data-end=\"4219\"\u003e\n\u003ctd data-start=\"4177\" data-end=\"4201\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4201\" data-end=\"4219\"\u003e-40°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4220\" data-end=\"4250\"\u003e\n\u003ctd data-start=\"4220\" data-end=\"4237\" data-col-size=\"sm\"\u003eHumidity Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4237\" data-end=\"4250\"\u003e10–90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4251\" data-end=\"4284\"\u003e\n\u003ctd data-start=\"4251\" data-end=\"4268\" data-col-size=\"sm\"\u003ePressure Range\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4268\" data-end=\"4284\"\u003e700–1300 hPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4285\" data-end=\"4336\"\u003e\n\u003ctd data-start=\"4285\" data-end=\"4300\" data-col-size=\"sm\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4300\" data-end=\"4336\"\u003eApprox. 2 years (24\/7 operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4337\" data-end=\"4384\"\u003e\n\u003ctd data-start=\"4337\" data-end=\"4351\" data-col-size=\"sm\"\u003eAlarm Types\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4351\" data-end=\"4384\"\u003eAudible, visual and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4385\" data-end=\"4439\"\u003e\n\u003ctd data-start=\"4385\" data-end=\"4406\" data-col-size=\"sm\"\u003eSensor Replacement\u003c\/td\u003e\n\u003ctd data-start=\"4406\" data-end=\"4439\" data-col-size=\"sm\"\u003eReplaceable sensor and filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4440\" data-end=\"4505\"\u003e\n\u003ctd data-start=\"4440\" data-end=\"4452\" data-col-size=\"sm\"\u003eApprovals\u003c\/td\u003e\n\u003ctd data-start=\"4452\" data-end=\"4505\" data-col-size=\"sm\"\u003eATEX, IECEx \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch1 data-section-id=\"6p42fr\" data-start=\"4512\" data-end=\"4554\"\u003eWhy Choose IM\u0026amp;M for the Dräger Pac 8000?\u003c\/h1\u003e\n\u003cp data-start=\"4556\" data-end=\"4703\"\u003eAs an experienced supplier of industrial safety equipment, IM\u0026amp;M can help you select the correct Dräger Pac 8000 configuration for your application.\u003c\/p\u003e\n\u003cp data-start=\"4705\" data-end=\"4935\"\u003eWhether you require a standard toxic gas monitor or a specialist configuration for gases such as \u003cstrong data-start=\"4802\" data-end=\"4832\"\u003eNO₂, HCN, PH₃, O₃ or COCl₂\u003c\/strong\u003e, our technical team can advise on the correct sensor option, accessories and calibration requirements.\u003c\/p\u003e\n\u003cp data-start=\"4937\" data-end=\"5032\"\u003e\u003cstrong data-start=\"4937\" data-end=\"5032\"\u003eNeed a different gas configuration? Contact our team for availability and technical advice: \u003ca href=\"https:\/\/www.im-m.co.uk\/pages\/contact\" title=\"Contact Us\"\u003eContact Us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"IMM-UK","offers":[{"title":"Nitrogen Dioxide (NO2 LC) \/ P\/N: 8326342","offer_id":53874938675311,"sku":null,"price":765.59,"currency_code":"GBP","in_stock":true},{"title":"Hydrogen Phosphide (PH3) \/ P\/N: 8326342","offer_id":53874938708079,"sku":null,"price":765.59,"currency_code":"GBP","in_stock":true},{"title":"Hydrogen Cyanide (HCN) \/ P\/N: 8326342","offer_id":53874938740847,"sku":null,"price":765.59,"currency_code":"GBP","in_stock":true},{"title":"Carbon Dioxide (CO2) \/ P\/N: 8326342","offer_id":53874938773615,"sku":null,"price":765.59,"currency_code":"GBP","in_stock":true},{"title":"Ammonia (NH3) \/ P\/N: 8326342","offer_id":53874938806383,"sku":null,"price":765.59,"currency_code":"GBP","in_stock":true},{"title":"Ethylene Oxide (EO) \/ P\/N: 8326342","offer_id":53874938839151,"sku":null,"price":765.59,"currency_code":"GBP","in_stock":true},{"title":"Nitrogen Monoxide (NO) \/ P\/N: 8326342","offer_id":53874938871919,"sku":null,"price":765.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0589\/1411\/1599\/files\/D-8538-2023_50.jpg?v=1784813215","url":"https:\/\/www.im-m.co.uk\/products\/drager-pac%c2%ae-8000-single-gas-detector","provider":"IMM-UK","version":"1.0","type":"link"}